Calculator

Roots Blower Power Estimator

Free Roots blower power estimator: ideal and shaft power from airflow, pressure rise and efficiency, plus the ideal air temperature rise. By AS Engineers.

  • ISO 9001:2015 · TÜV certified
  • 25+ years · 3000+ customers
  • Engineered to your process

Power estimator

How much power does your Roots blower need?

Set the airflow, the pressure rise and the efficiency. See the ideal and the estimated shaft power, and the air temperature rise.

0 kWestimated shaft power
Ideal (adiabatic) power
0 kW
Discharge pressure (absolute)
0 kPa
Ideal air temperature rise*
0 °C
Get this duty reviewed by an engineer

*Indicative only. Ideal power uses the adiabatic (isentropic) formula for air at 1.01325 bar and 20 °C. Shaft power divides it by the efficiency you enter. Real blowers have slip, losses and gear and bearing friction, so use the maker's curve for the real figure.

How the numbers work

What the estimator does, and what it does not

Ideal power uses the adiabatic formula for air. Shaft power divides it by the efficiency you enter. The temperature rise is the ideal value for air at 20 °C.

Ideal power

The least power needed to move that volume of air through that pressure rise with no losses.

Shaft power

Ideal power divided by overall efficiency. A real blower also has slip and friction, so the maker’s curve gives the true figure.

Temperature rise

Air heats as it is pushed to higher pressure. A larger pressure rise gives a hotter discharge, which matters for clearances and materials.

What it leaves out

A real selection needs more than this

Slip, speed, gear and bearing losses, inlet and outlet pressure losses, altitude, noise and the real duty cycle all decide the machine. That is why we ask for your duty data and review it.

Engineering Method Behind the Roots Blower Power Estimator

1. Swept displacement vs. net delivered airflow (slip allowance)

A rotary lobe Roots blower does not seal with piston rings; synchronized timing gears hold non-contacting rotor-to-rotor and tip-to-casing clearances between roughly 0.10 and 0.35 mm. At zero pressure difference, net delivered capacity nearly equals theoretical swept volume (Q_disp = V_rev * RPM). Once discharge backpressure rises against submerged ETP diffusers or pneumatic conveying piping, compressed air leaks backward through those micron clearances into the suction cavity (Q_slip). Net actual process delivery becomes Q_actual = Q_disp - Q_slip, where Q_slip grows roughly with the square root of differential pressure divided by gas density (sqrt(Delta P / rho)). When you size a package, always enter total swept displacement (Q_actual + Q_slip) into shaft power calculations because the motor compresses every cubic metre swept inside the casing, including internal slip backflow.

2. Differential kPa motor power formula and drive headroom

Because compression occurs externally against header pressure rather than adiabatically inside closed rotor pockets, bare-shaft Roots power scales directly with swept volume and differential pressure in kilopascals (Delta P_kPa, where 1,000 mmWC = 9.807 kPa and 1 bar = 100 kPa). Use kW_shaft = (Q_swept_m3min * Delta P_kPa) / (60 * eta_mech), where eta_mech (around 0.92 to 0.95) accounts for timing gear and spherical bearing friction. Divide by belt or coupling drive efficiency (eta_drive ~0.95 for matched V-belts, ~0.985 direct coupled) to determine required motor output, then verify at least 15% to 20% headroom above peak relief-valve cracking pressure (+10% to +15% above duty) so temporary diffuser fouling or pipeline surges never trip thermal relays. Follow every worked step in our Roots blower motor sizing guide.

3. Adiabatic discharge temperature check and acoustic hood limits

Rising pressure ratio heats discharge gas rapidly according to ideal adiabatic compression (T_2 = T_1 * (P_2 / P_1)^((k - 1) / k), with k = 1.4 for dry air in Kelvin), plus additional heat from internal clearance slip churning back into the intake pocket. For example, compressing 40 C summer air across 0.60 bar g raises theoretical adiabatic discharge temperature past +55 C and real outlet temperatures above 105 to 115 C, risking elastomer coupling failure, synthetic oil oxidation, or uneven rotor expansion against end plates. Inspect troubleshooting thresholds in why a Roots blower runs hot. Where acoustic enclosures are fitted to meet OSHA 85 dB(A) workplace noise norms, ensure forced hood ventilation prevents ambient intake temperature from climbing further. Above ~4,000 m3/h below 1,800 to 2,100 mmWC, check our centrifugal blower vs Roots blower selection guide before finalizing your specification.

Engineering references: Volumetric displacement and slip acceptance testing follow ISO 1217 (iso.org), and plant blower enclosure acoustic limits reference OSHA 29 CFR 1910.95 (osha.gov) and AMCA 210 (amca.org).

Before you ask

Six facts that let an engineer review your duty

Do not worry if you do not have all of them. Send what you know and we will ask for the rest.

1Airflow

Volume needed, in m3/min or m3/hr, and whether it is at inlet conditions.

2Pressure

Pressure rise across the blower, or the line and tank resistance, in kPa or mbar.

3Duty

Pressure (blowing), vacuum (suction) or both, and whether it runs continuous or intermittent.

4Air and site

Inlet air temperature, dust, altitude, and whether the air must be oil-free.

5Drive

Power supply, speed control needs and noise limits.

6Use

The process it serves, for example conveying, aeration or vacuum, and a layout sketch.

Want this checked by an engineer?

Send your numbers with the use. We reply within one working day.

Request your free quote

Step 1 of 2 · takes 30 seconds
What do you need?

Airflow, if you know it (m³/min)

No spam · reply within one working day

Where should we send your proposal?

Prefer to talk? +91 99090 33851 · WhatsApp

Ready when you are

Right blower for your duty. Honest engineering advice.

Tell us your airflow, pressure and use. We reply with plain advice within one working day.

[ase_paddle_divider]
Chat with us
Secure form

Get your duty reviewed

Step 1 of 2 · takes 30 seconds
What do you need?

Airflow, if you know it (m³/min)

No spam · reply within one working day

Where should we send your proposal?

Prefer to talk? +91 99090 33851 · WhatsApp

SSL-encrypted. Your details go only to our engineers – never shared or sold.