How to Size a Roots Blower Motor: Shaft kW, V-Belt Losses, Relief Peak & Headroom

In short

The adiabatic power formula for a Roots blower, a worked example for 20 m3/min at 50 kPa, and why the maker's curve gives the real figure.

By Karan Dargode, Manager, Operations & EHS, AS Engineers. Updated on November 26, 2026.

Sizing an electric motor for a Roots blower from delivered ETP airflow alone without adding internal rotor slip, mechanical belt losses, and relief-valve opening peaks causes chronic thermal overload trips during peak summer pressure swings. Unlike dynamic centrifugal wheels whose power drops when intake throttles shut, positive-displacement shaft power climbs practically proportionally with every kilopascal of downstream backpressure. This step-by-step calculation guide explains how to size a Roots blower motor transparently from ISO 1217 fundamentals alongside positive-displacement engineering physics.

In short: Key motor sizing checkpoints for Roots skids

  • Multiply SWEPT displacement by Delta P, NOT net delivered flow: The shaft compresses total swept displacement (Q_actual + Q_slip), so slip energy shows up directly on your ammeter!
  • Add 4% to 8% mechanical friction + V-belt transmission loss: Timing gears, two shaft bearings, and V-belt tension pull constant parasitic load at rated RPM.
  • Check relief-valve cracking pressure (+10% to +15% above duty): An ETP blower rated at 0.50 bar g must survive 0.55 to 0.58 bar g while venting safely without stalling the drive motor.
  • Watch VFD low-frequency cooling limits: Roots torque remains nearly constant across RPM; below ~25-30 Hz standard TEFC motors overheat unless fitted with forced-cooling blowers!
  • Cross-check centrifugal drive efficiency easily: Compare dynamic vs positive-displacement power formulas on Fan Laws calculation guides and ETP aeration engineering.

Plant teams served: Electrical engineers, utility supervisors, ETP design teams, and maintenance heads verifying skid motor plates before commissioning.

What is the exact Roots blower shaft power & motor HP formula?

For: Utility engineer, electrical specifier

Because a Roots blower uses external constant-volume compression (Delta P * Q_swept) rather than adiabatic internal blade compression, total mechanical brake power at the bare blower input shaft follows one reliable linear equation:

Roots Bare-Shaft Power Equation (SI Metric):

kW_shaft = (Q_swept_m3min * DeltaP_kPa) / 60 + kW_mech_friction

And accounting for mechanical gear/bearing efficiency (eta_mech typically ~0.92 to 0.96) plus V-belt/coupling drive efficiency (eta_drive ~0.95 for matched V-belts, ~0.985 for direct flex coupling):

kW_motor_input = (Q_swept_m3min * DeltaP_kPa) / (60 * eta_mech * eta_drive)

Where:

  • Q_swept_m3min = Q_actual + Q_slip in m3/min (never forget to add slip back into required flow!).
  • DeltaP_kPa = Discharge Pressure (kPa) - Suction Pressure (kPa) (Note: 1 bar = 100 kPa = 10,197 mmWC; 1 kg/cm2 = 98.07 kPa; so 5,000 mmWC = 49.03 kPa).

Worked Calculation: Sizing an ETP Diffused Aeration Motor Step-by-Step

For: Design engineer, ETP procurement

Suppose an industrial ETP plant needs 1,080 m3/h (18.0 m3/min) net oxygen supply delivered through submerged membrane diffusers sitting at 5.2 m water submergence plus pipe/silencer/diffuser losses adding 800 mmWC, totaling 6,000 mmWC (58.84 kPa) differential pressure across the blower:

  1. Add internal slip (say 13% at 0.59 bar g for chosen tri-lobe frame): Required swept displacement Q_swept = 18.0 / (1 - 0.13) = 20.69 m3/min.
  2. Compute theoretical compression work: (20.69 * 58.84) / 60 = 20.29 kW.
  3. Apply timing-gear/bearing efficiency (0.94) + V-belt drive efficiency (0.95): Required motor shaft output = 20.29 / (0.94 * 0.95) = 22.72 kW.
  4. Check relief-valve margin (+15% peak during fouled diffuser shock -> 67.7 kPa): Peak transient load hits 22.72 * (67.7 / 58.84) = 26.14 kW.
  5. Final Motor Selection: A 22 kW (30 HP) motor would run permanently overloaded whenever diffusers foul slightly or relief cracks! Step up cleanly to the next standard IEC frame: 30 kW (40 HP), 4-pole IE3 TEFC motor (~13% peak reserve headroom above worst-case fouled line pressure!).
Duty Scenario & FlowRequired Delta PApprox Swept Flow (incl. Slip)Estimated Bare Shaft PowerRecommended Standard IE3 Motor Frame
Light ETP (3.5 m water + pipe) @ 600 Am3/h4,000 mmWC (39.2 kPa)~11.2 m3/min~7.9 kW11 kW (15 HP)
Deep ETP (5.2 m water + diffuser) @ 1,080 Am3/h6,000 mmWC (58.8 kPa)~20.7 m3/min~22.7 kW (peak 26.1 kW)30 kW (40 HP)
Positive Pneumatic Transfer @ 1,800 Am3/h5,000 mmWC (49.0 kPa)~34.1 m3/min~31.1 kW37 kW (50 HP)

Five electrical & VFD traps when powering positive-displacement skids

For: Electrical engineer, commissioning team

  1. Using Variable-Torque VFD curves instead of Constant-Torque mode: Centrifugal fans follow cube torque drop (set VFD to quadratic V/f). Roots blowers maintain flat constant torque down to 25 Hz: setting quadratic V/f stalls the blower at low speed! Always configure VFD for Constant Torque (CT) / heavy-duty overload (150% for 60s).
  2. Running an uncooled standard motor continuously at 20 to 25 Hz: Standard motor-shaft cooling fans stall slowly at 25 Hz while full load current stays high; add an external forced-cooling motor fan above 30% continuous turndown range.
  3. Forgetting high ambient derating (45 to 50 C India utility sheds): Check NEMA/IEC temperature rise derating tables if your blower sits inside a closed unventilated acoustic hood.
  4. Leaving overloaded belts loose or mismatched: Tight over-tensioned V-belts overload blower drive-end bearings rapidly, while slipping belts drop RPM and choke slip capacity.
  5. Ignoring centrifugal energy savings below 2,000 mmWC: Above ~3,000 to 5,000 m3/h below 1,800 mmWC, verify high-pressure centrifugal blower curves rather than burning extra kW on rotary lobes!

Frequently Asked Questions on Sizing Roots Blower Motors

Why do I use swept displacement instead of net airflow to calculate motor kW?

The electric motor drives the rotors across the full internal swept cavity against discharge pressure; gas slipping backward through lobe gaps still absorbs compression work and turns straight into discharge heat (kW_shaft depends on swept flow times Delta P).

How much reserve headroom should a Roots blower motor have above normal shaft power?

Maintain at least 15% to 20% headroom above normal design shaft kW (or exceed peak relief-valve cracking load) so temporary diffuser fouling or clogged bag filters never trip overload relays.

Can I run a Roots blower slower with a VFD to save electricity?

Yes, proportionally! Cutting RPM by 20% drops delivered flow by ~20-25% and shaft power linearly by roughly 20%, using constant-torque VFD settings with forced motor cooling if sustained below ~30 Hz.

Does AS Engineers supply complete blower and motor selection calculations?

Yes. Founded in 1997 in Vatva, Ahmedabad (ISO 9001:2015), AS Engineers provides clear thermodynamic shaft power sheets alongside custom centrifugal and air-system engineering packages.

Your next step by department

  • Utilities & Electrical: Confirm peak diffuser/pipe Delta P, relief valve cracking setting, ambient shed temperature, and VFD minimum Hz range before locking motor HP.
  • Procurement & Maintenance: Require IE3/IE4 forced-cooled motor specs whenever wide turndown VFDs are paired with constant-torque skids.
  • Take action: Verify your motor HP and duty calculation using our online estimator or contact our engineering desk.

About the author: Karan Dargode leads Operations and EHS at AS Engineers in Vatva, Ahmedabad, where he has managed shop-floor manufacturing, assembly, and on-site equipment commissioning since 2019. He holds a B.E. in Mechanical Engineering from GTU and a PGDBA in Operations from Symbiosis. Connect with Karan on LinkedIn.

Sources

  • International Organization for Standardization: ISO 1217 Displacement Compressors Acceptance Tests (iso.org).
  • International Electrotechnical Commission: IEC 60034-30-1 Efficiency Classes of Line-Operated AC Motors (IE3/IE4) (iec.ch).
  • Bureau of Energy Efficiency (BEE), Government of India: Electric Motors & Blower System Audits (beeindia.gov.in).
  • US Department of Energy (DOE): Variable Frequency Drives & Positive Displacement System Controls (energy.gov).
Written by Karan Dargode Manager – Operations & EHS, AS Engineers
  • B.E. Mechanical · GTU (2018)
  • PGDBA, Operations · Symbiosis
  • With AS Engineers since 2019
  • Writes on blowers, fans & plant reliability

Karan Dargode leads operations and environmental health & safety at AS Engineers, the Ahmedabad manufacturer of centrifugal blowers, bag filters, pneumatic conveying systems and paddle dryers. He writes practical guides on blowers, material handling and plant reliability.

Tell us your duty. We will say which blower fits.

Share the airflow, pressure rise and use. Get plain advice on Roots or centrifugal within one working day.

Request your free quote

Step 1 of 2 · takes 30 seconds
What do you need?

Airflow, if you know it (m³/min)

No spam · reply within one working day

Where should we send your proposal?

Prefer to talk? +91 99090 33851 · WhatsApp

Ready when you are

Right blower for your duty. Honest engineering advice.

Tell us your airflow, pressure and use. We reply with plain advice within one working day.

[ase_paddle_divider]
Chat with us
Secure form

Get your duty reviewed

Step 1 of 2 · takes 30 seconds
What do you need?

Airflow, if you know it (m³/min)

No spam · reply within one working day

Where should we send your proposal?

Prefer to talk? +91 99090 33851 · WhatsApp

SSL-encrypted. Your details go only to our engineers – never shared or sold.