In short
The adiabatic power formula for a Roots blower, a worked example for 20 m3/min at 50 kPa, and why the maker's curve gives the real figure.
By Karan Dargode, Manager, Operations & EHS, AS Engineers. Updated on November 26, 2026.
Sizing an electric motor for a Roots blower from delivered ETP airflow alone without adding internal rotor slip, mechanical belt losses, and relief-valve opening peaks causes chronic thermal overload trips during peak summer pressure swings. Unlike dynamic centrifugal wheels whose power drops when intake throttles shut, positive-displacement shaft power climbs practically proportionally with every kilopascal of downstream backpressure. This step-by-step calculation guide explains how to size a Roots blower motor transparently from ISO 1217 fundamentals alongside positive-displacement engineering physics.
In short: Key motor sizing checkpoints for Roots skids
- Multiply SWEPT displacement by Delta P, NOT net delivered flow: The shaft compresses total swept displacement (
Q_actual + Q_slip), so slip energy shows up directly on your ammeter! - Add 4% to 8% mechanical friction + V-belt transmission loss: Timing gears, two shaft bearings, and V-belt tension pull constant parasitic load at rated RPM.
- Check relief-valve cracking pressure (+10% to +15% above duty): An ETP blower rated at 0.50 bar g must survive 0.55 to 0.58 bar g while venting safely without stalling the drive motor.
- Watch VFD low-frequency cooling limits: Roots torque remains nearly constant across RPM; below ~25-30 Hz standard TEFC motors overheat unless fitted with forced-cooling blowers!
- Cross-check centrifugal drive efficiency easily: Compare dynamic vs positive-displacement power formulas on Fan Laws calculation guides and ETP aeration engineering.
Plant teams served: Electrical engineers, utility supervisors, ETP design teams, and maintenance heads verifying skid motor plates before commissioning.
What is the exact Roots blower shaft power & motor HP formula?
For: Utility engineer, electrical specifier
Because a Roots blower uses external constant-volume compression (Delta P * Q_swept) rather than adiabatic internal blade compression, total mechanical brake power at the bare blower input shaft follows one reliable linear equation:
Roots Bare-Shaft Power Equation (SI Metric):
kW_shaft = (Q_swept_m3min * DeltaP_kPa) / 60 + kW_mech_friction
And accounting for mechanical gear/bearing efficiency (eta_mech typically ~0.92 to 0.96) plus V-belt/coupling drive efficiency (eta_drive ~0.95 for matched V-belts, ~0.985 for direct flex coupling):
kW_motor_input = (Q_swept_m3min * DeltaP_kPa) / (60 * eta_mech * eta_drive)
Where:
Q_swept_m3min=Q_actual + Q_slipin m3/min (never forget to add slip back into required flow!).DeltaP_kPa=Discharge Pressure (kPa) - Suction Pressure (kPa)(Note:1 bar = 100 kPa = 10,197 mmWC;1 kg/cm2 = 98.07 kPa; so5,000 mmWC = 49.03 kPa).
Worked Calculation: Sizing an ETP Diffused Aeration Motor Step-by-Step
For: Design engineer, ETP procurement
Suppose an industrial ETP plant needs 1,080 m3/h (18.0 m3/min) net oxygen supply delivered through submerged membrane diffusers sitting at 5.2 m water submergence plus pipe/silencer/diffuser losses adding 800 mmWC, totaling 6,000 mmWC (58.84 kPa) differential pressure across the blower:
- Add internal slip (say 13% at 0.59 bar g for chosen tri-lobe frame): Required swept displacement
Q_swept = 18.0 / (1 - 0.13) = 20.69 m3/min. - Compute theoretical compression work:
(20.69 * 58.84) / 60 = 20.29 kW. - Apply timing-gear/bearing efficiency (0.94) + V-belt drive efficiency (0.95): Required motor shaft output =
20.29 / (0.94 * 0.95) = 22.72 kW. - Check relief-valve margin (+15% peak during fouled diffuser shock -> 67.7 kPa): Peak transient load hits
22.72 * (67.7 / 58.84) = 26.14 kW. - Final Motor Selection: A 22 kW (30 HP) motor would run permanently overloaded whenever diffusers foul slightly or relief cracks! Step up cleanly to the next standard IEC frame: 30 kW (40 HP), 4-pole IE3 TEFC motor (~13% peak reserve headroom above worst-case fouled line pressure!).
| Duty Scenario & Flow | Required Delta P | Approx Swept Flow (incl. Slip) | Estimated Bare Shaft Power | Recommended Standard IE3 Motor Frame |
|---|---|---|---|---|
| Light ETP (3.5 m water + pipe) @ 600 Am3/h | 4,000 mmWC (39.2 kPa) | ~11.2 m3/min | ~7.9 kW | 11 kW (15 HP) |
| Deep ETP (5.2 m water + diffuser) @ 1,080 Am3/h | 6,000 mmWC (58.8 kPa) | ~20.7 m3/min | ~22.7 kW (peak 26.1 kW) | 30 kW (40 HP) |
| Positive Pneumatic Transfer @ 1,800 Am3/h | 5,000 mmWC (49.0 kPa) | ~34.1 m3/min | ~31.1 kW | 37 kW (50 HP) |
Five electrical & VFD traps when powering positive-displacement skids
For: Electrical engineer, commissioning team
- Using Variable-Torque VFD curves instead of Constant-Torque mode: Centrifugal fans follow cube torque drop (set VFD to quadratic V/f). Roots blowers maintain flat constant torque down to 25 Hz: setting quadratic V/f stalls the blower at low speed! Always configure VFD for Constant Torque (CT) / heavy-duty overload (150% for 60s).
- Running an uncooled standard motor continuously at 20 to 25 Hz: Standard motor-shaft cooling fans stall slowly at 25 Hz while full load current stays high; add an external forced-cooling motor fan above 30% continuous turndown range.
- Forgetting high ambient derating (45 to 50 C India utility sheds): Check NEMA/IEC temperature rise derating tables if your blower sits inside a closed unventilated acoustic hood.
- Leaving overloaded belts loose or mismatched: Tight over-tensioned V-belts overload blower drive-end bearings rapidly, while slipping belts drop RPM and choke slip capacity.
- Ignoring centrifugal energy savings below 2,000 mmWC: Above ~3,000 to 5,000 m3/h below 1,800 mmWC, verify high-pressure centrifugal blower curves rather than burning extra kW on rotary lobes!
Frequently Asked Questions on Sizing Roots Blower Motors
Why do I use swept displacement instead of net airflow to calculate motor kW?
The electric motor drives the rotors across the full internal swept cavity against discharge pressure; gas slipping backward through lobe gaps still absorbs compression work and turns straight into discharge heat (kW_shaft depends on swept flow times Delta P).
How much reserve headroom should a Roots blower motor have above normal shaft power?
Maintain at least 15% to 20% headroom above normal design shaft kW (or exceed peak relief-valve cracking load) so temporary diffuser fouling or clogged bag filters never trip overload relays.
Can I run a Roots blower slower with a VFD to save electricity?
Yes, proportionally! Cutting RPM by 20% drops delivered flow by ~20-25% and shaft power linearly by roughly 20%, using constant-torque VFD settings with forced motor cooling if sustained below ~30 Hz.
Does AS Engineers supply complete blower and motor selection calculations?
Yes. Founded in 1997 in Vatva, Ahmedabad (ISO 9001:2015), AS Engineers provides clear thermodynamic shaft power sheets alongside custom centrifugal and air-system engineering packages.
Your next step by department
- Utilities & Electrical: Confirm peak diffuser/pipe Delta P, relief valve cracking setting, ambient shed temperature, and VFD minimum Hz range before locking motor HP.
- Procurement & Maintenance: Require IE3/IE4 forced-cooled motor specs whenever wide turndown VFDs are paired with constant-torque skids.
- Take action: Verify your motor HP and duty calculation using our online estimator or contact our engineering desk.
About the author: Karan Dargode leads Operations and EHS at AS Engineers in Vatva, Ahmedabad, where he has managed shop-floor manufacturing, assembly, and on-site equipment commissioning since 2019. He holds a B.E. in Mechanical Engineering from GTU and a PGDBA in Operations from Symbiosis. Connect with Karan on LinkedIn.
Sources
- International Organization for Standardization: ISO 1217 Displacement Compressors Acceptance Tests (iso.org).
- International Electrotechnical Commission: IEC 60034-30-1 Efficiency Classes of Line-Operated AC Motors (IE3/IE4) (iec.ch).
- Bureau of Energy Efficiency (BEE), Government of India: Electric Motors & Blower System Audits (beeindia.gov.in).
- US Department of Energy (DOE): Variable Frequency Drives & Positive Displacement System Controls (energy.gov).
- B.E. Mechanical · GTU (2018)
- PGDBA, Operations · Symbiosis
- With AS Engineers since 2019
- Writes on blowers, fans & plant reliability
Karan Dargode leads operations and environmental health & safety at AS Engineers, the Ahmedabad manufacturer of centrifugal blowers, bag filters, pneumatic conveying systems and paddle dryers. He writes practical guides on blowers, material handling and plant reliability.